kurumsal@kayrapatent.com.tr +90 (232) 364 49 0309:0018:00
RegionsWorldwide ServicesArticles
Kayra PatentKAYRAPATENTRequest a QuoteENEN
CE · Vibrating screen

CE conformity for Vibrating screen

For Vibrating screen, the applicable CE scope is determined from intended use, energy sources, safety architecture and target market. The risk assessment, technical file, testing and conformity route must be verified against the actual model.

CE conformity for Vibrating screen — Product-specific conformity guide
Producing movementExcentric mile, vibration engine or synchronous drive combination
Carrier systemA mobile body with a bow or elastomer mesenchment and a fixed main chassis
Worn partsWire mesh, polyurethane panel, handcuffs, shutter and bow
The process variablesWidth, frequency, slope, distribution of feed and material moisture
Direct response to the scope

CE conformity for Vibrating screen — Define the product boundary first

The body of the vibrating handle is constantly shaken by an eccentric mile, vibrating engine or mass mechanism; wide and variable compression zones form between the fixed structure and the moving parts. The surrounding platform, shutter, cable and dust cover may lose the designed openings if assembled differently from the manufacturer's location.

The maintenance frequency is high as the electrical wires and modular panels are replaced as they break. The panel friction mechanism can suddenly empty, heavy caps can fall, and the body can move in a sloping position. The safe working method must include power cutting, mechanically fixing the moving casing, appropriate lifting point, access platform, and correct friction control of the new panel.

If there is a monitoring system, alarm locks are justified by mechanical mechanics; showing vibration value on the screen alone is not a protective measure. Covered lids and sawdust connections in dry thin material, water carrying, slippery surfaces and corrosion resistant electrical equipment are separate design decisions.

Product profile

Technical features that change the evaluation

The following data shows why even models with the same product name can change the path of conformity.

Producing movementExcentric mile, vibration engine or synchronous drive combination
Carrier systemA mobile body with a bow or elastomer mesenchment and a fixed main chassis
Worn partsWire mesh, polyurethane panel, handcuffs, shutter and bow
The process variablesWidth, frequency, slope, distribution of feed and material moisture
Risk architecture

The main dangers to be addressed in the file

The protective, control and verification approach shall be based on the actual product cycle.

01

Compression with the moving body

The electrical box can grip the hand and body by approaching a fixed platform or shoots, and the surrounding distance, barrier, and forbidden area are determined together.

02

Arrow and friction energy

A broken bow or a strained panel connection can be suddenly drained during dismantling.

03

The drop of the material

The stone can be leaked from the feeding and discharge shafts or poured into the maintenance level.

04

Structural fatigue

The continuous dynamic load source can create cracks in the casing and carrier.

05

Stirring catch points

Snow-mil, belt, torpedo or vibration engine weights are a moving hazard.

06

Dust, noise and slippery

Dry ground breathable dust and noise; wet grounding creates a mixture of water and rock and a slippery ground.

The conditional law matrix

When will the regulation take effect?

A single product name doesn't give the same answer for all models.

The subjectThe situationProduct-based evaluation
The machine's layoutYES, YESIn Turkey, 2006/42/AT is applied for vibratory waste; the next national compliance is confirmed on the date of the first market supply or first service of the waste. The stimulus system is examined in this context.
EMCIT 'S A MESS .EMC scope is assessed in terms of the intended environment; driver and communication patterns affect test requirements.
LVDNO , NOT AT ALL .The LVD is not applied to machinery as a separate directive; electrical safety objectives are met within the scope of machinery legislation.
PEDNO , NOT AT ALL .The standard vibrational handle's motion and handling function is not pressure equipment; if a special pressure auxiliary system is added, this result is reassessed.
ATEXIT 'S A MESS .If coal, grain or combustible chemical dust is absorbed, ATEX coverage may occur depending on the zone, dust layer and engine-bed temperature.
The slippage processIT 'S A MESS .If spraying or washing is required, the degree of electrical protection, drainage, corrosion and working platform slip are also designed.

Standard and verification approach

  • EN 1009-1: It provides the basis for general protection, access, control and information requirements of mineral processing equipment.
  • EN 1009-2: It is used in transport hazards caused by waste from feeding and discharge equipment.
  • EN 1009-4: Assesses the specific provisions concerning the dynamic movement, material flow and maintenance hazards of the machines.
  • EN ISO 12100: It deals with task and failure scenarios from setup to panel change with risk reduction hierarchy.
  • EN ISO 14122 series: It supports the design of stairs, platforms, scaffolding and transitions that last for high tide.
  • EN ISO 13849-1 and -2: Protective locks, safe stand-ups, or surveillance alarms are used in risk-reducing design and verification.
  • EN 60204-1: If the coverage of electrical equipment is appropriate, the cable motion part shall be applied, including the motor control and protective linkage; it shall not be automatically assigned.
Important distinction

CE conformity for Vibrating screen — Product conformity is a separate study.

ISO management system certification does not replace product-specific risk analysis, test evidence and compliance file.

The compliance work plan

In what order will the technical preparation proceed?

Defining dynamic design

Width, frequency, mass, bow order, slope and permitted material load are fixed in the technical profile.

Check the installation interface

Distance is controlled in the settlement by the movement of the chassis, platform, shooter, cable, hose and hood.

Developing a maintenance scenario

The mechanical fixation, lifting and access method is specified in the panel, bow, motor and bed change.

Measurement and function test

The vibration, noise, posture, lock, alarm and if any, the exhaust performance are recorded at the actual load.

Do not close the technical file

Setup tolerances, wear limits, periodic examination and remaining risks are linked to the report by the guide.

Product records to search for in the technical file

  • General and motion envelope drawings
  • Dynamic load and chassis calculations
  • Risk assessment
  • Technical documents for the bow-target panel
  • Electrical and sensor schemes
  • Platform details with cache
  • Vibration and noise test recordings
  • Structural inspection and plan of the scaffolding
  • Panel-shaped change instructions
  • In Turkey, 2006/42/AT requires an AT Declaration of Conformity in the EC file. For electricity, the EU/AEA includes 2006/42/EC on 19 hob 2027; the EC Declaration of Conformity is used in the EC file. This unit of reference shall apply to the EU Declaration of Conformity from 20 hob 2027 (EU) 2023/1230.

They 're the entries for a healthy offer .

  • The width- height of the elec and the number of layers
  • Width, frequency and type of stimulus
  • Material, capacity and range
  • Working on dry or wet
  • Arrow, chassis and platform layout
  • Link to the dust cap
  • Current account and prototype tests

The electrical dimension does not indicate the duration of operation alone; it determines the maturity of dynamic calculations, maintenance platforms, explosive dust probability, and field integration scope.

Frequently Asked Questions

CE conformity for Vibrating screen — Technical answers about

How much space should be left around the vibrating handle?

There is no single universal measure, but the manufacturer determines the installation size based on the maximum movement envelope, fixed structure, access and associated safety distances.

Is the bow breaking sensor mandatory?

Risk analysis determines the impact of the fracture and the test solution, and if the sensor is used, the machine's response is confirmed with the reliability of the sensing.

What energies should be fixed in the electrical panel change?

The moving body must be mechanically fixed, the friction energy must be controlled and heavy parts must be transported appropriately.

Can the dust cover be attached to the moving body?

The connection must be dynamically load-friendly, leak-proof and maintenance-safe.

What calculations will the vibration engine change affect?

Changes in mass momentum, torque or power affect movement envelope and structural loads.

Does the slippery slope completely eliminate the need for ATEX?

The material may not consistently form sufficiently wet and explosive clouds, but general results cannot be obtained without examining the conditions of drying, maintenance and adjacent equipment.

Technical scope and offer

CE conformity for Vibrating screen — Let us clarify your technical file together.

Share the model of the machine or device, the location of use and the basic technical data. The Kayra Patent explains the path to be followed for scope analysis, technical preparation, test plan and, where necessary, approved organization coordination.

Ask for expert opinion and suggestions

Final inspection of content and technical scope: 20 August 2026The official bases: European Commission Machinery · EUR-Lex — EU 2023/1230
Live support